The University of Southern California Teaching Hospital in east Los Angeles (1991) had a severe test in 1994, when the Northridge earthquake.........More From
USC University Hospital, California: The Tested U.S. Base Isolated Building
Swelling and shrinkage due to the property of volumetric changes of expansive soil like black cotton soil results movement of the ground producing cracking........More From
Under-Reamed Piles: Safest Foundation Solution for Black Cotton soil
















= 0.5*0.12*8.75

= 0.525 k/ft

3.1.7 UPWARD SOIL PRESSURE :

Upward soil pressure at the bottom slab may calculated from the following-

  1. From top slab including fill

= 0.1125 + 0.672 + 0.02

= 0.8045 k/ft2

  1. From vertical wall

= ( 2*0.75*0.15*4 ) / length of culvert

= ( 2*0.75*0.15*4 ) / ( 2*0.75+4*1 )

= 0.164 k/ft2

3. From wheel load

= 1.1428/length of culvert

= 1.1428 / ( 1*4+2*0.75 )

= 0.21 k/ft2

4. From bottom slab

= 0.75*0.15

= 0.1125 k/ft2

5. Water pressure = 64*4/1000

= 0.26 k/ft2

Total vertical pressure on foundation soil

= ( 0.8025+0.164+0.21+0.1125+0.26 ) k/ft2

= 1.55 k/ft2


3.1.8 LOAD ON BOX CULVERT :

  1. Top slab load (uniformly distributed) = 0.81k/ft

  1. Top slab load (concentrated),

Rear wheel = 1.1428 k/ft

Front wheel = 0.2857 k/ft

  1. Bottom slab load = 1.55 k/ft

  1. Side wall load at top = 0.525 k/ft

  1. Side wall load at bottom = 0.81 k/ft

  1. Surcharge load = 0.156 k/ ft

3.1.9 CALCULATION OF DISTRIBUTION FACTOR :

Moment of inertia,

IAB = bh3 /12

= 12*93 /12

= 729 in4 [consider 1 ft strip]

Stiffness,

kAB =I/L [center line dimension]

= 729/57

= 12.8

IAB = 729 in4

KAB = 12.8

IAC = 12*9 / 12

= 729 in4

KAC = 729 / 57

= 12.8

Distribution factor,

DAB = 12.8 / (12.8+12.8)

= 0.50

DAC = 12.8 / (12.8+12.8)

= 0.50

DBA = 12.8 / (12.8+12.8)

= 0.50

3.1.10 CALCULATION OF FIXED END MOMENT :

MAB = -wl2 /12-Pl/8

= -0.81*4.752 /12-1.143*4.75/8

= -2.202 k-ft

MBA = 2.202 k-ft

MAC = Pl2 /12+wl2 /30

= (0.156+0.525)*4.752 /12+(0.81-0.525)*4.752 /30

= 1.49 k-ft

MCA = -Pl2 /12-wl2 /20

= -(0.156+0.525)*4.752 /12-(0.81-0.525)*4.752 /20

= - 1.6 k-ft

MCD = wl2 /12

= 1.55*4.75/12

= 2.91 k-ft

MDC = -2.91 k-ft




In case of concealed slab

Effective width, E = 1.75 * 8

= 14 ft.



Therefore, let us assume, the dispersion width is 14 ft considering following provisions of PCA manual, AASHTO-92, section 3.8.2.3,


Impact factor for wheel load, I = 0.0%

Weight of each vertical wall = 4 * 0.15 * 1 [consider 1 ft strip]

= 0.6 k/ft


The transmission and distribution of wheel loads through soil generally assumed to follow the principles of elasticity.

When the depth of fill is less than 2 ft, AASHTO specifies that, the wheel load be distributed as an exposed slab, when the depth of fill is more than 2 ft, concentrated loads are to be uniformly distributed over a square, the side of which are equal to 1.75 times the depth of fill.

Therefore, concentrated load ( conceal slab ) :


Live load from rear wheel, per ft of slab


= {16(1+Impact factor/100)}/14

= 1.1428 k/ft [Impact factor = 0%]


Live load from front wheel, per ft width of slab,

= {4(1+Impact factor/100)}/14

= 0.2857 k/ft


Concentrated load ( exposed slab ) with no impact

= 16 ( 1+0/100 ) / 4.57

= 3.5 k


3.1.6 SIDE WALL LOAD :

Coefficient of active earth pressure is calculated by using the Rankine’s formula,

ka = (1-sin 300) / (1+sin300 )

= 0.33

But in our case, we consider co-efficient of active earth pressure at rest condition,

ka = (1-sin 300 )

= 0.5


The effect of live load surcharge when acting along ( with approach slab), will be uniformly lateral load.


Uniformly lateral load due to surcharge equivalent to 2.6ft earth fill



h= 8+9/12+4+9/12

= 13.5

h1 = 8+9/12

= 8.75

Lateral pressure at the bottom of vertical wall

= 0.5*0.12*13.5

= 0.81 k/ft

Lateral pressure at centerline of top slab